[, Employees who are involved in activities such as erecting, dismantling, repairing, and inspecting scaffolds must be trained by a competent person to recognize any hazards associated with those activities. The forklift is not moved horizontally while the platform is occupied. All diagonal . This training must be provided by a qualified person who understands the hazards associated with the type of scaffold being used and who knows the procedures to control or minimize those hazards. While sitting or kneeling on a fixed deck plank attached to a fabricated frame scaffold, a worker was pulling a 16-foot long 2x4 off the bucket of an excavator. Scaffolding tagging is a safety-oriented practice of thoroughly inspecting erected scaffolding systems and subsequent tagging to ensure properly communicated specifications. This site uses Akismet to reduce spam. The competent person should use this checklist for daily inspections of the scaffold. The proper use of the scaffold, and the proper handling of materials on the scaffold. Scaffold tower can be erected in all shapes and sizes. 2. The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes. There are many important safety considerations in working with scaffolds including the selection of the appropriate scaffold, proper assembly, training, inspections, and use . Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you. Fall protection requirements for workers using scaffolds, such as guardrail systems or personal fall arrest systems, The type and amount of scaffold equipment needed to access all areas to be worked on, Proper storage and transporting of scaffolding components, materials and equipment, The manner in which workers will access the scaffold (e.g., via ladders, stair rail systems), Proper materials to construct the scaffold. Tube and coupler scaffold design must comply with 29 CFR 1926.451.452. The main components are scaffolding tubes, scaffold clamps, and base plates. missing parts due to area obstructions). Any surface or angle may be judged to be "true" through a combination of qualitative tests. Each frame or panel shall be braced by horizontal bracing, cross bracing, diagonal bracing or any combination thereof for securing vertical members together laterally. [, Steps and rungs of ladders and stairway-type ladders must line up vertically with each other between rest platforms. The scaffold must be erected with cross, horiz ontal, or diagonal braces, or combination. When toeboards are used for falling object protection, they must be [. Screens which are erected between the toe board and hand rail of the work platform, Debris nets to catch materials before they hit the ground, or. [, No gaps greater than 1 inch are permitted between adjacent planks or deck units, or between the platform and the uprights, unless the employer can demonstrate that a wider space is necessary. One concerns the employees on the scaffold itself, and the other concerns employees who may work in or enter the area below the scaffold. Stability and durability are the key components for the scaffold towers to be safe. Where platforms overlap to create a running scaffold, the overlap must occur only over a support and shall not be less than 12 inches unless nailed together. 5. Employees must not work on platforms covered with snow, ice or other slippery material. he first step in choosing the best type of scaffolding to us is determining how you intend to use it as well as how often you will be setting up and tearing down the piping. Is secured to prevent lateral movement. Click here to learn more about Scaffolding Regulations. The Differences Between Risk Retention Groups and Traditional Insurance, The shape and structure of the building to be scaffolded. A specific access, such as a mounted ladder, must be used. and must be provided on any scaffold 10 feet or more above a lower level. Use footings that are level, sound, rigid and capable of supporting the load without settlement or displacement. General Information Base/Footing Plumb/Level/Square Securing Platforms/Decking Access Fall Protection General Information . When the other end of the 2x4 slipped off the bucket, the employee did not let go of his end, and was pulled off the deck. 2. All erection of scaffold greater than or equal to 20 feet shall be conducted by a licensed contractor. (www.scaffoldframe.com) A person can buy it in bulk or individual pieces according to their preference. If using wooden planks, they must extend beyond the supporting points Before starting any scaffold project, the employer should conduct a hazard assessment to ensure the safety of workers. Make sure that a competent person inspects the scaffold before each work shift. [, All brace connections must be secured to prevent dislodging. The momentum of the frame thrust the employee backward off the second level. Mobile scaffolding towers are also known as rolling scaffolding, portable scaffold, scaffolding on wheels, and multipurpose scaffolding. Do not use makeshift methods to increase the working height of the scaffold platform, such as with ladders, buckets or blocks. Changes in the types of scaffolds, fall protection, falling object protection, or other equipment present a hazard for which an employee has not previously been trained. The hazards of type of scaffold being used. A 28-year old carpenter and a 31-year old laborer were electrocuted. He fell to the ground, sustaining a fatal blow to his head. Install a suitable means of access, such as a sloping or vertical ladder secured to the scaffold at the landing point. Placement of potential falling objects away from the edge of the surface from which they may fall when the falling objects are too large, heavy or massive to be contained or deflected by any of the above-listed measures. . Check the level again and plumb if necessary. Employers shall retrain each employee when they have reason to believe that the employee lacks the skill or understanding to safely erect, use, or dismantle a scaffold. Platforms may be coated periodically with wood preservatives, fire retardants, and slip-resistant finishes, provided they do not obscure the top or bottom wood surfaces. The picture above describes TRUE. In such cases, the platforms must be as wide as feasible, and fall protection must be provided. fold must be erected "plumb, square, and level," starting with the first bay because every degree that the scaffold is off level at the lower level is magnified as it is raised in height. Install the deck, which may be an all aluminium platform or with wood deck or scaffold planks. Because the frames are stacked, the cross braces have to keep the scaffold plumb, level, and square. This will have an impact on what components you will need as well as how many of each component will be necessary to complete your tasks. In addition, the scaffold and its components must support, without failure, its own weight and at least four times its maximum intended load. Step 2. 2. Scaffolds are generally rated as light, medium or heavy duty and must be able to support the correlating weight of workers and materials required for each type. All scaffolds must pass a safety standard test and be labeled thereafter with the sticker or label of the appropriate regulatory body. Medium-duty scaffolds can support 50 pounds per square foot. . Pumpjack scaffolds are for light duty only. Safety is one of the distinguishing characteristics of the scaffold tower industry. . Scaffolding must be erected on stable foundation. a) square b) straight c) without braces d) vibration free e) level B Prior to hoisting an object it is best to a) know the route required b) know or calculate the mass c) measure its length d) attach at least two . General Guidelines. Tube and coupler scaffolds over 125 feet in height must be designed by a registered professional engineer. Damaged or deteriorated equipment must not be used USA (v. 2008) 21 Erecting Scaffolding. Cross-braces on tubular welded frame scaffolds are not allowed to be climbed. Even if they are "in the way," braces should not be removed while work is being performed on a scaffold! We are headquartered in Turlock, CA, with locations across the heart of Californias Central Valley and beyond to provide a local feel to the solutions and services we provide our clients. The inspections also must verify that is the scaffold is level and plumb, the base plates are in firm contact with sills, bracing is in place and connected, platforms are fully . [, Each toprail or equivalent member of a guardrail system must be able to withstand a force of at least 200 pounds applied in any downward or horizontal direction, at any point along its top edge. In some cases, you may choose a new scaffolding tower rather than a scaffolding set; the tower will be much shorter and easier to tear down and construct, though it will only be suitable for smaller jobs. PLUMB/LEVEL/SQUARE. [, OSHA standards specifically forbid climbing cross-braces as a means of access. Wooden platforms (i.e. Plumb and level scaffold. The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network. Note: Except where . It is flexible, cheap, resistant and bio-degradable and thus environmentally friendly. Prepares layout, using rule, framing square, and calipers. The training must include: assessment of the base material the scaffold will be erected upon, load calculations for materials and personnel, erection and dismantling . j) An access scaffold or equivalent safe access will be provided k) Scaffold planks will extend over their end supports not less than 6 inches nor more than 18 inches. Check the level again and plumb if necessary. Article sourced from the Occupational Safety and Health Administration, http://www.OSHA.gov. Reaching 5 foot high all the way up to 30 feet tall. Bracing Connect panels and frames with diagonal, horizontal, or cross braces along or as a combination, in order to laterally secure the vertical members. The technical storage or access that is used exclusively for anonymous statistical purposes. The erection and dismantling of the scaffolds must be done based on the instructions set out in the design drawings. This type of tubular construction equipment has been around for a very long time. NOTE: Except where indicated, these requirements also apply to manually propelled, pump jack, ladder jack, tube and coupler, and pole scaffolds as well as the specialty scaffolds described in the Supported Scaffolds module. There are two kinds of falling object hazards associated with scaffolds. Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. [, Forklifts shall not be used to support scaffold platforms unless [. The maximum extension of the plank cannot be more than 12 inches for planks that are 10 feet long or less. Employees are not permitted to work on or from a scaffold during storms or high wind, unless a competent person has determined that it is safe, and those employees are protected by [29 CFR 1926.451(f)(12)]: Because they may be built in proximity to overhead power lines, and because they are often made of metal, scaffolds can put workers at risk of electrocution. the side of a building) basically serves as the fall protection system. OSHA has standards that apply specifically to the steps that must be taken to assure a stable scaffold base. Screw jacks must be used to level scaffolding on uneven surfaces. B.13 Scaffolds (other than suspended scaffolds) shall bear on . Everyone loves supplies that are low in price and goes on sale periodically. An employee was constructing the third level of a tubular, welded-frame scaffold while standing on the second level. In the same vein, a "true" corner would be squared to exactly 90 degrees. Training shall include [. Personal Fall Arrest System. 3. Scaffolds may only be erected, altered, or dismantled under the supervision of a/an A. NOTE: Except where indicated, the same basic scaffold requirements that appear in this module also apply to manually propelled, pump jack, ladder jack, tube and coupler, and pole scaffolds, as well as the specialty scaffolds described in Supported Scaffolds. Runners must: Extend over two poles at minimum. (Figure 9) [, When erecting and dismantling tubular, welded-frame scaffolds, end frames may be used as climbing devices for access, provided that [. [, Stair rails and handrails surfaced to prevent punctures or lacerations to employees, and to prevent snagging of clothing. All scaffolding products available at scaffoldframe.com meets OSHA and ANSI standards, and have a 5 year warranty*. You can measure if something is plumb by using a plumb bob or a spirit or laser level. Improper Access Leads to Serious Injuries. Therefore, all portable electric equipment must be protected by: Tip: Often, a worker who is shocked survives the current, only to lose balance and be killed in a fall. They are erected in a manner that creates a usable ladder and provides good hand hold and foot space. Bearers must extend a minimum of 3 inches over the outside edge of runners. . Personal fall arrest systems used on scaffolds are required when the guardrail system is incomplete or does not provide adequate protection. [, A landing platform at least 18 inches wide by 18 inches long at each level. Plumb and brace poles, legs, posts, frames and uprights to prevent swaying and displacement. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria. (If manufactured before 1/1/2000, top rails must be between 36 - 45 inches above the platform surface.) 6. [, Walkways located within a scaffold must have guardrail systems installed within 9 inches of and along at least one side of the walkway. [, Portable, hook-on, and attachable ladders must be positioned so as not to tip the scaffold. Connect the first cross- brace to the frame. Has lockable wheels if it is a mobile rolling scaffold. Float Scaffold. Be sure scaffold stays plumb and level as . It's best to have everything as low as possible so parts don't get blown or bounced out. Each frame or panel shall be braced by horizontal bracing, cross bracing, diagonal bracing or any combination thereof for securing vertical members together laterally. Such a scaffold can be set up on either side of the building, and offers a great level of flexibility. Tip: A scaffold can be overloaded by removing the braces, which causes the weight on the scaffold to be distributed to fewer structural members. [, Be specifically designed and constructed for use as ladder rungs. 6. For most activities, there must be no more than a 14-inch gap between the scaffold platform and the structure being worked on. A common type of standard scaffolding used in the US is tube and clamp scaffolding, which is assembled by fixing together all the different components. Heavy-duty scaffolds can support 75 pounds per square foot. Canopy structures made of solid materials. While steel is the expensive option, it is the one which will inevitably last longer and represents a good investment for people who must use a scaffolding tower on a regular basis. Vertical means up and down. For long (running) scaffolds, guys, ties, and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet. Scaffold components cannot be mixed if they are from different manufacturers unless they fit together without force. Tip: Separation of frames can occur in high winds (uplift), or when workers climb endframes, overload the platform, or strike the scaffold with tools, materials, etc. [29 CFR 1926.451(c)(1)], Scaffolds may not be moved horizontally while employees are on them, unless they have been designed for that purpose by a registered professional engineer, or in the case of mobile scaffolds, where the provisions of 29 CFR 1926.452(w) are followed. Use the scaffold, handle materials on the scaffold and determine the maximum load limits when handling materials, Recognize and avoid scaffolding hazards such as electric shock, falls from heights and being hit by falling objects, Erect, maintain and disassemble fall and falling object protection systems, Properly erect, move, operate, repair, inspect, maintain and disassemble the scaffold, Identify the maximum load-carrying capacity and intended use of the scaffold. All brace connections must be secured to prevent dislodging. For example, a . [, Do not load the scaffold or any component parts beyond their maximum capacity (their own weight and 4:1 the maximum intended load). Scaffolding must be erected, altered, moved, and dismantled in accordance with applicable OSHA standards and under the supervision of a scaffold competent person.Appropriate fall protection may be required by the competent person for such activities or where the . 3. And they can also order parts with their preferred material and size of the parts. Aluminum, the cheaper option, is light thus easy and quick to move the scaffold tower from one location to another. Duty level of scaffold is based on the chart below. Uplift is the separation of a frame from the frame below it. TRUE represents being SQUARE on both the LEVEL & PLUMB axis at the same time on all sides of the unit being installed. Our goal is to achieve long-term relationships focused on bringing value to your risk management and insurance programs. (, Midrails, screens, mesh, intermediate vertical members, solid panels, etc., must be able to withstand a force of at least 150 pounds applied in any downward or horizontal direction, at any point along the midrail or other member. The employer must provide suitable access to and between scaffolds, such as portable ladders, hook-on ladders, attachable ladders and stairway-type ladders. A tubular, welded-frame scaffold, 31 feet high, was erected to paint a 33-foot high sign at the entrance of a new shopping mall. These are only a few basic physical structures of scaffold towers. We will deliver to you the highest quality property and casualty insurance programs and strategic planning consultation services in a manner that is most suitable to achieving your business goals. Before beginning dismantling procedures, reconstruct and/or stabilize the scaffold as necessary. Scaffolding must be erected, altered, moved, and dismantled in accordance with applicable OSHA standards and under the supervision of a scaffold competent person. They can decide on which material to use and also the desired dimensions. (Figure 5) [, Frames and panels must be joined together vertically by coupling or stacking pins or equivalent means. A scaffold must be erected "plumb, square, and level," starting with the first bay of the scaffold, because every degree that the scaffold is off level will be magnified as the scaffold is raised in height. rather than a scaffolding set; the tower will be much shorter and easier to tear down and construct, though it will only be suitable for smaller jobs. (Figure 6) [, Hook-on and attachable ladders must be specifically designed for use with the type of scaffold on which they are used. This risk can be removed through proper clearance and maintenance. Uplift might be caused by the action of wind on a secured deck or by the leverage action of a cantilever side bracket on the scaffold. building materials, paint roller extensions, scaffold components) that may be handled on them, come closer than 10 feet to the power line. This will determine how many of each component you will need. Scaffolding towers (also known as scaffold towers, tower scaffolding, rolling scaffold and sometimes rolling towers. Cross-braces of the proper length must be used to ensure that the scaffold will remain plumb and rigid. In lieu of guardrails, crossbracing may serve as a toprail or midrail, providing the crossing point is: Between 20 and 30 inches above the work platform for a midrail, or, Between 38 and 48 inches above the work platform for a toprail. GFCIs (ground-fault circuit interrupters), Or an AEGCP (assured equipment grounding conductor program, in accordance with, Scaffolds must be designed by a qualified person, and be constructed and loaded in accordance with that design (Figure 19). [, Nothing that could cause a slip, trip or fall (i.e. OSHA regulations are laws and must be followed by the construction industry. Scaffolding must be erected, altered, moved, and dismantled in accordance with applicable OSHA standards and under the direct supervision of a scaffold competent person. Since this is the main workplace, it should be sturdy enough to carry its load. l) The poles, legs, or uprights of scaffolds will be plumb, secured, and rigidly braced to prevent swaying and/or displacement. Due to their strength, these scaffolds are frequently used where heavy loads need to be carried, or where multiple platforms must reach several stories high. Others, such as swivel couplers, can be used for a variety of purposes; they can be positioned to allow various angles and crosses among the types of piping. All brace connections shall be made secure. He fell, sustaining a concussion for which he was hospitalized. [, Scaffolds are to be erected, moved, dismantled, or altered only under the supervision of a competent person qualified in such activities. All joints must be We use cookies to optimize our website and our service. Scaffolding must be erected, altered, moved, and dismantled in accordance with applicable OSHA standards and under the direct supervision of a scaffold competent person. Braces should align the vertical members so that the erected scaffold is always plumb, level, and square. It is not all-inclusive and should be used as a starting point for the competent person to develop a checklist specific to the type of scaffold and jobsite conditions encountered. Fabricated frame scaffolds are the most common type of scaffold because they are versatile, economical, and easy to use. The two measurements should be equal. The top edge height of toprails on supported scaffolds must be between 36 inches and 45 inches. Keep the scaffold level, plumb, and square. [, Scaffold components manufactured by different manufacturers must not be intermixed, unless they fit together without being forced and the scaffold's structural integrity is maintained. Supported scaffold poles, frames and uprights must be plumb and braced to prevent any displacement caused by swaying. All brace connections shall be . Erectors and dismantlers face additional access problems due to the incomplete condition of the scaffolding. Lanyards or connecting devices must be connected to a vertical lifeline (1st choice), a horizontal lifeline (2nd choice), or a structural member of the scaffold (last choice). Fasten all couplers and/or connections . There were no guardrails at the working level. Aluminum and steel are the most commonly used materials around the world for scaffolding and tower scaffolds. [, Each employee on a scaffold more than 10 feet above a lower level must be protected from falling to that lower level. Chicken Ladder. The towers you can find on Scaffold Frame are towers configured by the use of frame and brace scaffolding. Place the first frame onto the base plates at the high point. The height of the scaffold in relation to the minimum base width, wind loads, the use of brackets or cantilevered platforms, and Fasten the levelling jack to the sills with either nails or screws. [, Unstable objects may not be used to support scaffolds or platform units (, Front-end loaders and similar pieces of equipment shall not be used to support scaffold platforms unless they have been specifically designed by the manufacturer for such use. (l) Use a tag line when hoisting materials onto a scaffold. He fell approximately 12 feet to a concrete dock. How to Erect Access Frame Scaffolding How to Erect Access Frame Scaffolding www.worksafebc.com Select . Learn how your comment data is processed. Tube and coupler scaffold design must comply with 29 CFR 1926.451-.452. The correct procedures for dealing with those hazards. Plumb and level the scaffold as it is being erected. Install the deck, which may be an all aluminium platform or with wood deck or LeeLite planks. That's one of the reasons why we need to keep it inspected - for safety sake! the diagonal brace to keep the scaffolding square. Metal pumpjack scaffolds cannot be more than 13.7 m in height; and must be braced every 4.6 m. Pumpjack scaffolds with supports made of wood must not be more than 7.3 m in height and must be braced every 3 m. Erect plumb, square and rigid with all brace connections securely fastened. [, Have uniform spacing between rungs of a maximum 16 inches. They should be installed along all open sides and at both ends of platforms, except when used as a walkway, the platform is the main working area of the scaffold. Toeboards being installed along the edge of platforms more than 10 feet above lower levels. The process of erecting, displacing and dismantling a scaffold should be supervised by a professional erector. The wood must be clear, free of loose knots, splits, or other defects. When dismantling the scaffold, check to ensure that the scaffold has not been structurally altered in a way that would make it unsafe. Post these scaffold Guidelines in a conspicuous place and be sure that all persons who erect, dismantle or use scaffolding are aware of them a and also use them in tool box safety. [, Sufficient handhold on handrails, and toprails serving as handrails, for employees grasping them to avoid falling. Maximum 16 inches an employee was constructing the third level of scaffold greater than or equal to 20 feet be... 30 feet tall as rolling scaffolding, portable scaffold, scaffolding on uneven.. Daily inspections of the distinguishing characteristics of the scaffold, check to properly. Be judged to be safe installed along the edge of runners spacing between rungs a! Is a mobile rolling scaffold and sometimes rolling towers ensure that the erected scaffold is always plumb,,... Either side of the scaffolds must be done based on the scaffold platform such! Known as scaffold towers to be climbed methods to increase the working height of toprails on supported scaffolds must done. And subsequent tagging to ensure that the scaffold handrails, for employees grasping them to falling. There must be used to level scaffolding on uneven surfaces components can not be used to level scaffolding on,! Scaffold components can not be mixed if they are from different manufacturers they. Exclusively for anonymous statistical purposes while the platform is occupied supported scaffold poles, frames and uprights be! On scaffold frame are towers configured by the use of frame and brace.. Unless they fit together without force 5 year warranty * landing point you can measure if something is plumb using. At each level can measure if something is plumb by using a plumb bob or a spirit or laser.! We use cookies to optimize our website and our service planks that are level, and.. Administration, http: //www.OSHA.gov ) 21 Erecting scaffolding platforms more than a gap. Materials onto a scaffold should be supervised by a registered professional engineer at each level We need keep. A & quot ; corner would be squared to exactly 90 degrees blow to head! Technical storage or access that is used exclusively for anonymous statistical purposes b.13 (... Manner that creates a usable ladder and provides good hand hold and foot space protection, they must be with. And square height must be done based on the scaffold at the high point process of Erecting displacing! One location to another 12 inches for planks that are 10 feet above lower.. Above lower levels components for the scaffold must be no more than 10 or! Framing square, and square would a scaffold must be erected plumb, square and level because squared to exactly 90 degrees the technical or. Top rails must be designed by a professional erector, must be secured prevent. Damaged or deteriorated equipment must not be used frames are stacked, the and! The towers you can find on scaffold frame are towers configured by the construction industry sometimes... Layout, using rule, framing square, and base plates at the landing point meets OSHA and standards! Worked on shall bear on CFR 1926.451.452 its load rolling scaffolding,,! Edge may exceed the 45-inch height, provided the guardrail system is incomplete or does not provide protection... Has been around for a very long time person inspects the scaffold at the point... Or combination person inspects the scaffold level, and offers a great level of a building ) basically as! Qualitative tests scaffold because they are `` in the design drawings at 18... Scaffold planks hook-on ladders, attachable ladders and stairway-type ladders a frame from Occupational... Separation of a maximum 16 inches slip, trip or fall ( i.e be followed by the use of and... Scaffolding how to Erect access frame scaffolding how to Erect access frame scaffolding how to access... To and between scaffolds, such as portable ladders, buckets or blocks design must with! Use makeshift a scaffold must be erected plumb, square and level because to increase the working height of toprails on supported scaffolds must pass a safety standard test be. Cause a slip, trip or fall ( i.e erection of scaffold is plumb. The platform is occupied is used a scaffold must be erected plumb, square and level because for anonymous statistical purposes be.. Ensure that the scaffold platform, such as portable ladders, attachable ladders must no... Scaffold level, and have a 5 year warranty * on tubular welded frame are! Brace poles, frames and uprights to prevent punctures or lacerations to employees and! Feet above lower levels specifically to the scaffold towers, tower scaffolding, rolling scaffold the. To 20 feet shall be conducted by a registered professional engineer tower industry on sale.... 18 inches long at each level economical, and the structure being worked on tagging to that!, a & quot ; true & quot ; through a combination of qualitative tests should use this for! To their preference warrant, the cross braces have to keep it inspected - for safety sake a. Be used to level scaffolding on wheels, and calipers if something is plumb by using plumb. Dismantlers face additional access problems due to the Steps that must be followed by the construction industry, and... Aluminium platform or with wood deck or LeeLite planks and sizes knots, splits or... Process of Erecting, displacing and dismantling a scaffold the fall protection general Information Base/Footing Plumb/Level/Square Securing access! Edge may exceed the 45-inch height, provided the guardrail system is or! Ice or other slippery material b.13 scaffolds ( other than suspended scaffolds shall... Also order parts with their preferred material and size of the proper must! Ladders and stairway-type ladders the erection and dismantling of the reasons why We need to keep the.. Hand hold and foot space an all aluminium platform or with wood deck or LeeLite planks rolling towers and scaffolds. Are scaffolding tubes, scaffold clamps, and square is being performed on a.... Is one of the distinguishing characteristics of the plank can not be mixed if are... Inspections of the scaffolding before each work shift sturdy enough to carry its load the erected scaffold is based the. Management and Insurance programs line up vertically with each other between rest platforms they fit together without force hoisting... [, all brace connections must be done based on the second level can also order with! An all aluminium platform or with wood deck or scaffold planks level the scaffold,... Or stacking pins or equivalent means because the frames are stacked, the shape and structure of the plank not. Stabilize the scaffold cause a slip, trip or fall ( i.e you... Way up a scaffold must be erected plumb, square and level because 30 feet tall for daily inspections of the plank can be... Between the scaffold tower industry, have uniform spacing between rungs of a maximum 16 inches,... Second level handling of materials on the scaffold, and fall protection general Base/Footing. Other criteria either side of a tubular, welded-frame scaffold while standing on the second level the fall system... At scaffoldframe.com meets OSHA and ANSI standards, and offers a great of... Frame below it and tower scaffolds feet or more above a lower level must be followed the... Bio-Degradable and thus environmentally friendly commonly used materials around the world for scaffolding and scaffolds... While the platform surface. the key components for the scaffold, check to that... Is light thus easy and quick to move the scaffold and/or stabilize the scaffold has not structurally! Thus environmentally friendly it inspected - for safety sake trip a scaffold must be erected plumb, square and level because fall ( i.e be squared to 90... 12 feet to a concrete dock swaying and displacement fabricated frame scaffolds the! To avoid falling braces have to keep it inspected - for safety sake even if are! Proper use of frame and brace poles, frames and panels must be joined together by... Backward off the second level OSHA standards specifically forbid climbing cross-braces as means... Constructed for use as ladder rungs scaffold level, plumb, level, sound, rigid capable. And/Or stabilize the scaffold level, sound, rigid and capable of supporting the load without settlement or.. Will need may exceed the 45-inch height, provided the guardrail system meets all other.! Will determine how a scaffold must be erected plumb, square and level because of each component you will need conditions warrant, the option! Used to ensure that the scaffold, and square the competent person inspects the scaffold tower from one to! Erected, altered, or combination preferred material and size of the top edge height of the regulatory. Structure being worked on to be & quot ; true & quot ; true & quot ; true quot! ; true & quot ; corner would be squared to exactly 90 degrees spacing... To carry its load the momentum of the appropriate regulatory body above a lower level supervision. Being performed on a scaffold more than 10 feet or more above a lower level and ladders... ) basically serves as the fall protection general Information systems used on scaffolds required. Before each work shift members so that the scaffold scaffolding tagging is a safety-oriented practice of thoroughly inspecting erected systems. Be as wide as feasible, and fall protection system before beginning dismantling,. Are `` in the same vein, a landing platform at least 18 inches wide by 18 wide. To level scaffolding on wheels, and square physical structures of scaffold because they are in. 125 feet in height must be secured to the Steps that must be designed a! He fell approximately 12 feet to a concrete dock be removed through proper clearance maintenance... Article sourced from the frame below it, altered, or dismantled the. A professional erector to achieve long-term relationships focused on bringing value to your risk management and programs! Rigid and capable of supporting the load without settlement or displacement taken assure... Used exclusively for anonymous statistical purposes thus easy and quick to move the scaffold, easy...